SCS-317

7-day Programmable Thermostat

Include : Setup ZWave / Learn

Exclude : Setup ZWave / Learn

Associate : Setup ZWave / Associate Node

SSR-302

2-channel relay

Include : Press and hold both white buttons

Exclude : Press and hold both white buttons

Activate : Hold channel button, press Green (on) or Red (off)

Wiring

From (Grant) Combi boiler:

  • L (brown) to L
  • N (blue) to N
  • Switched CH-On (green/yellow!) to 4

SSR302 internal electronics provide permanent Live (L) to switched outputs (1, 2, 3, 4).

Switched outputs are:

  • 1: Z2 OFF (active high)
  • 2: Z1 OFF (active high)
  • 3: Z2 ON
  • 4: Z1 ON

Observations:

  • the SSR-302 zones are swapped (1&3 is Z2, 2&4 is Z1)
  • SCS-317 only operates Z1.
  • No external link between L and 2 should be used - unlike in the ASR-ZW

SCS-317 and SSR-302 association

  • Include SSR-302
  • Include SCS-317
  • Remove SCS-317 associations

Associate SCS-317 and SSR-302

  • Send HA a NIF from the SCS-317 to synchronize associations with HA
  • On the SCS-317 ZWave setup menu, associate node
  • Press and Hold both white buttons on SSR-302