SCS-317
7-day Programmable Thermostat
- Include
- Setup ZWave? / Learn
- Exclude
- Setup ZWave? / Learn
- Associate
- Setup ZWave? / Associate Node
SSR-302
2-channel relay
- Include
- Press and hold both white buttons
- Exclude
- Press and hold both white buttons
- Activate
- Hold channel button, press Green (on) or Red (off)
Wiring
From (Grant) Combi boiler:
- L (brown) to L
- N (blue) to N
- Switched CH-On (green/yellow!) to 4
SSR302? internal electronics provide permanent Live (L) to switched outputs (1, 2, 3, 4).
Switched outputs are:
- 1: Z2 OFF (active high)
- 2: Z1 OFF (active high)
- 3: Z2 ON
- 4: Z1 ON
Observations:
- the SSR-302 zones are swapped (1&3 is Z2, 2&4 is Z1)
- SCS-317 only operates Z1.
- No external link between L and 2 should be used - unlike in the ASR-ZW
SCS-317 and SSR-302 association
- Include SSR-302
- Include SCS-317
- Remove SCS-317 associations
Associate SCS-317 and SSR-302
- Send HA a NIF from the SCS-317 to synchronize associations with HA
- On the SCS-317 ZWave? setup menu, associate node
- Press and Hold both white buttons on SSR-302